Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Manual Type /Electric Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SRM3DC-320 | SRM3DC-400 | |||||||
Rated current of shell frame grade Inm(A) | 320 | 400 | |||||||
Rated current In(A) | 20,32,63,80,100,125,140,160,180 200,225,250,280,315,320 |
225,250,315 350,400 |
|||||||
Pole Number | 2 | 3 | 2 | 3 | |||||
Rated working voltage Ue(V)DC | 500 | 1000 | 1500 | 250/500 | 750/1000 | 1250/1500 | 1250/1500 | ||
Rated insulation voltage Ui(V) | 1250 | 1500 | 1500 | ||||||
Rated impulse withstand voltage Uimp(kV) | 8 | 12 | 12 | ||||||
Extreme short-circuit breaking capacity Icu (kA) |
H Type | 50 | 20 | 20 | 65 | 35 | 15 | 15 20 | |
R Type | / | / | 1 | 70 | 40 | 20 | 20 25 | ||
Running short-circuit breaking capacity Ics (kA) |
H Type | Ics=100%lcu | |||||||
R Type | |||||||||
Wiring mode | Up incoming and Down outcoming,Down incoming and Up outcoming (2P,320/3P) Down incoming and Down outcoming,Up incoming and Up outcoming (3P) |
||||||||
Mechanical life (Total times) | 20000 | 10000 | |||||||
Electrical life(Total times) | 3000 | 2000 | 1500 | 1000 | 1000 | 700 | 500 | ||
Insolation feature | Yes | ||||||||
Standard | EC 60947-2,GB/T 14048.2 | ||||||||
Allowable ambient temperature | -35~+70ºC | ||||||||
Levels of protection | IP20 | ||||||||
Quality certificate | cCC,CE,TUV certificate | ||||||||
With accessories | Auxiliary,alarm,off load,Hand operation,Electric operation | ||||||||
Arcing distance (mm) | ≤50 (Zero arc,with arcing cover) | ||||||||
Transient Action value | 10ln | ||||||||
Overall dimensions L×W×H(mm) |
L | 180 | 180 | 250 | 250 | ||||
W | 76 | 107 | 124 | 182 | |||||
H | 126 | 126 | 165 | 165 |
Model | SRM3DC-320 | SRM3DC-400 | |||||||
Rated current of shell frame grade Inm(A) | 320 | 400 | |||||||
Rated current In(A) | 20,32,63,80,100,125,140,160,180 200,225,250,280,315,320 |
225,250,315 350,400 |
|||||||
Pole Number | 2 | 3 | 2 | 3 | |||||
Rated working voltage Ue(V)DC | 500 | 1000 | 1500 | 250/500 | 750/1000 | 1250/1500 | 1250/1500 | ||
Rated insulation voltage Ui(V) | 1250 | 1500 | 1500 | ||||||
Rated impulse withstand voltage Uimp(kV) | 8 | 12 | 12 | ||||||
Extreme short-circuit breaking capacity Icu (kA) |
H Type | 50 | 20 | 20 | 65 | 35 | 15 | 15 20 | |
R Type | / | / | 1 | 70 | 40 | 20 | 20 25 | ||
Running short-circuit breaking capacity Ics (kA) |
H Type | Ics=100%lcu | |||||||
R Type | |||||||||
Wiring mode | Up incoming and Down outcoming,Down incoming and Up outcoming (2P,320/3P) Down incoming and Down outcoming,Up incoming and Up outcoming (3P) |
||||||||
Mechanical life (Total times) | 20000 | 10000 | |||||||
Electrical life(Total times) | 3000 | 2000 | 1500 | 1000 | 1000 | 700 | 500 | ||
Insolation feature | Yes | ||||||||
Standard | EC 60947-2,GB/T 14048.2 | ||||||||
Allowable ambient temperature | -35~+70ºC | ||||||||
Levels of protection | IP20 | ||||||||
Quality certificate | cCC,CE,TUV certificate | ||||||||
With accessories | Auxiliary,alarm,off load,Hand operation,Electric operation | ||||||||
Arcing distance (mm) | ≤50 (Zero arc,with arcing cover) | ||||||||
Transient Action value | 10ln | ||||||||
Overall dimensions L×W×H(mm) |
L | 180 | 180 | 250 | 250 | ||||
W | 76 | 107 | 124 | 182 | |||||
H | 126 | 126 | 165 | 165 |